Technical Specifications of HD22005-3 (HD11010-3)
The universal technical specifications of the rectifier are given in table HD22005-3-1 to table HD22005-3-4:
                    Table HD22005-3-1 Input characteristics of the rectifier
Item
Specifications
Input voltage
323V~475V (three-phase three-wire)
Input current
£4A
AC input frequency
50Hz±10%
Efficiency
³90%
Table HD22005-3-2 Output characteristics of the rectifier

Item
Specifications
Remarks
Output voltage range
198~286V
220V series
Output current
Rated output: 5A
The maximal output is 105%~110% of the rated value.
Voltage rise time
3~10 seconds
Soft startup time
Range of the output constant current
10%~110%
 
Precision of the stabilized current
£±1%
20% current limit test
Ripple coefficient of the output voltage
£0.1%
 
Precision of the stabilized voltage
£±0.5%
 
Temperature coefficient (1/℃)
£0.02%
 

Table HD22005-3-3 Protective characteristics of the rectifier

Item
Specifications
Remarks
Short circuit foldback of output
Foldback current £40% rated current, automatic recoverable
 
Protection of the output overvoltage
293±6VDC, unrecoverable and to be powered on again and restarted
No DC output after the protection
Alarm for the output undervoltage
191 ± 6VDC recoverable
DC output available after alarming
Protection of the input overvoltage
482 ±6VAC, recoverable with the recovery point of 460 ±15VAC
No DC output after the protection
Protection of the input undervoltage
316 ±6VAC, recoverable with the recovery point of 335 ±10VAC
No DC output after the protection
Phase failure protection
Recoverable
No DC output after the protection
Over-temperature protection
Over-temperature protection point: 85 ℃; Recovery point: 75 ℃.
Accuracy: ± 5 ℃
Fan temperature control
Fan start point: 50℃; Fan stop point: 38℃
Accuracy: ± 5℃

TableHD22005-3-4 Monitoring function description of the rectifier

No.
Item
Specifications
Remarks
1
Remotely acquiring alarm/digital signal
Transmit to the PCU the protection signals such as the AC overvoltage/ undervoltage, Phase failure, output overvoltage/undervoltage and rectifier overtemperature, and the fault signals of the rectifier.
 
2
Remotely acquiring analog signal
Measure the output voltage and current of the rectifier, and send them to the LED of rectifier for display and report to the PCU.
 
3
Remotely controling system state
Based on the commands of the PCU, control the on/off and boost/float charging of the rectifier.
The manual control is also furnished to shield the control of the PCU.
4
Remotely adjusting voltage analog signal
Based on the commands of the PCU, regulate the output voltage of the rectifier.
Based on the commands of the PCU, regulate the output current limiting threshold of the rectifier within the range of 10%~100%.
5
Display
The LED of the rectifier, which displays the output current and voltage of the rectifier, are under the control of the monitoring board in the rectifier.